Peer-reviewed studies from Phantomics and our clinical partners. Each entry links to the original article at the publisher.
Purpose This study aimed to develop and validate a deep learning (DL) model to detect obstructive coronary artery disease (CAD, ≥ 50% stenosis) in coronary CT angiography (CCTA) among patients presenting to the emergency department (ED) with acute chest pain. Materials and methods The training dataset included 378 patients with acute chest pain who underwent CCTA (10,060 curved multiplanar reconstruction [MPR] images) from a single-center ED between January 2015 and December 2022. The external validation dataset included 298 patients from 3 ED centers between January 2021 and December 2022. A
Myocardial segmentation is crucial for accurate assessment of cardiac functions and pathology. Automatic segmentation of myocardial tissue from magnetic resonance (MR) images is actively researched especially with cine MR data that offer high spatial and temporal resolution. Challenges arise when processing cine images acquired from different scanner systems, as segmentation networks trained using one manufacturer’s images may perform poorly on another’s due to variations between training and test data distributions. Unsupervised domain adaptation addresses the domain shift issue by transferri
Purpose To evaluate the predictive value of deep learning (DL)-based coronary artery disease (CAD) extent analysis for major adverse cardiac events (MACEs) in patients with acute chest pain presenting to the emergency department (ED). Materials and Methods This retrospective multicenter observational study included consecutive patients with acute chest pain who underwent coronary CT angiography (CCTA) at three institutional EDs from January 2018 to December 2022. Patients were classified as having no CAD, nonobstructive CAD, or obstructive CAD using a DL model. The primary outcome was MACEs du
Aims T1 mapping on cardiac magnetic resonance (CMR) imaging is useful for diagnosis and prognostication in patients with light-chain cardiac amyloidosis (AL-CA). We conducted this study to evaluate the performance of T1 mapping parameters, derived from artificial intelligence (AI)-automated segmentation, for detection of cardiac amyloidosis (CA) in patients with left ventricular hypertrophy (LVH) and their prognostic values in patients with AL-CA. Methods and results A total of 300 consecutive patients who underwent CMR for differential diagnosis of LVH were analyzed. CA was confirmed in 50 pa
Objective This study investigated the feasibility and prognostic relevance of threshold-based quantification of myocardial delayed enhancement (MDE) on CT in patients with nonischemic dilated cardiomyopathy (NIDCM). Materials and Methods Forty-three patients with NIDCM (59.3 ± 17.1 years; 21 male) were included in the study and underwent cardiac CT and MRI. MDE was quantified manually and with a threshold-based quantification method using cutoffs of 2, 3, and 4 standard deviations (SDs) on three sets of CT images (100 kVp, 120 kVp, and 70 keV). Interobserver agreement in MDE quantification was
Cardiac diffusion weighted-magnetic resonance imaging (DWI) has slowly developed due to its technical difficulties. However, this limitation could be overcome by advanced techniques, including a stimulated echo technique and a gradient moment nulling technique. This study aimed to develop and validate a high-order DWI sequence, using echo-planar imaging (EPI) and second-order motion-compensated (M012) diffusion gradient applied to cardiac imaging in small-sized animals with fast heart and respiratory rates, and to investigate the feasibility of cardiac DWI, diagnosing acute myocardial injury i
A short-time cardiac imaging protocol added to breast MRI achieved excellent results for interscan and intercoil reproducibility and variability in ventricular functional or tissue characterization parameters in both healthy controls and participants with breast cancer who underwent chemotherapy. Purpose To investigate the feasibility and interscan variability of short-time cardiac MRI protocol after chemotherapy in individuals with breast cancer. Materials and Methods A total of 13 healthy female controls (mean age, 52.4 years ± 13.2 [SD]) and 85 female participants with breast cancer (mean a
Background: The reliability and diagnostic performance of deep learning (DL)-based automated T2 measurements on T2 map of 3.0-T cardiac magnetic resonance imaging (MRI) using multi-institutional datasets have not been investigated. We aimed to evaluate the performance of a DL-based software for measuring automated T2 values from 3.0-T cardiac MRI obtained at two centers. Methods: Eighty-three subjects were retrospectively enrolled from two centers (42 healthy subjects and 41 patients with myocarditis) to validate a commercial DL-based software that was trained to segment the left ventricular m
Objective To quantitatively analyze the cardiac magnetic resonance imaging (CMR) characteristics of chemotherapy-related cardiac dysfunction (CTRCD) and explore their prognostic value for major adverse cardiovascular events (MACE). Materials and Methods A total of 145 patients (male:female = 76:69, mean age = 63.0 years) with cancer and heart failure who underwent CMR between January 2015 and January 2021 were included. CMR was performed using a 3T scanner (Siemens). Biventricular functions, native T1 T2, extracellular volume fraction (ECV) values, and late gadolinium enhancement (LGE) of the
With the increased availability of magnetic resonance imaging (MRI) and a progressive rise in the frequency of cardiac device implantation, there is an increased chance that patients with implanted cardiac devices require MRI examination during their lifetime. Though MRI is generally contraindicated in patients who have undergone pacemaker implantation with electronic circuits, the recent introduction of MR Conditional pacemaker allows physicians to take advantage of MRI to assess these patients during diagnosis and treatment. When MRI examinations of patients with pacemaker are requested, phy
Objective This study aimed to develop and validate models using radiomics features on a native T1 map from cardiac magnetic resonance (CMR) to predict left ventricular reverse remodeling (LVRR) in patients with nonischemic dilated cardiomyopathy (NIDCM). Materials and Methods Data from 274 patients with NIDCM who underwent CMR imaging with T1 mapping at Severance Hospital between April 2012 and December 2018 were retrospectively reviewed. Radiomic features were extracted from the native T1 maps. LVRR was determined using echocardiography performed ≥ 180 days after the CMR. The radiomics score
Importance Dual-energy chest radiography exhibits better sensitivity than single-energy chest radiography, partly due to its ability to remove overlying anatomical structures. Objectives To develop and validate a deep learning–based synthetic bone-suppressed (DLBS) nodule-detection algorithm for pulmonary nodule detection on chest radiographs. Design, Setting, and Participants This decision analytical modeling study used data from 3 centers between November 2015 and July 2019 from 1449 patients. The DLBS nodule-detection algorithm was trained using single-center data (institute 1) of 998 chest
Objective T1 mapping provides valuable information regarding cardiomyopathies. Manual drawing is time consuming and prone to subjective errors. Therefore, this study aimed to test a DL algorithm for the automated measurement of native T1 and extracellular volume (ECV) fractions in cardiac magnetic resonance (CMR) imaging with a temporally separated dataset. Materials and Methods CMR images obtained for 95 participants (mean age ± standard deviation, 54.5 ± 15.2 years), including 36 left ventricular hypertrophy (12 hypertrophic cardiomyopathy, 12 Fabry disease, and 12 amyloidosis), 32 dilated c
We aimed to determine the effects of deep learning-based reconstruction (DLR) on radiomic features obtained from cardiac computed tomography (CT) by comparing with iterative reconstruction (IR), and filtered back projection (FBP). A total of 284 consecutive patients with 285 cardiac CT scans that were reconstructed with DLR, IR, and FBP, were retrospectively enrolled. Radiomic features were extracted from the left ventricular (LV) myocardium, and from the periprosthetic mass if patients had cardiac valve replacement. Radiomic features of LV myocardium from each reconstruction were compared usi
Background: Myocardial T2* mapping at 1.5T remains the gold standard, but the use of 3T scanners is increasing. We aimed to determine the conversion equations in different scanners with clinically available, vendor-provided T2* mapping sequences using a phantom and evaluated the feasibility of the phantom-based conversion method. Methods: T2* of a phantom with FeCl3 (five samples, 3.53–20.09 mM) were measured with 1.5T (MR-A1) and 3T scanners (MR-A2, A3, B), and the site-specific equation was determined. T2* was measured in the interventricular septum of three healthy volunteers at 1.5T (T2*1.
Objectives To investigate the effect of the phantom-based correction method for standardizing myocardial native T1 and extracellular volume fraction (ECV) in healthy subjects. Methods Seventy-one healthy asymptomatic adult (≥ 20 years) volunteers of five different age groups (34 men and 37 women, 45.5 ± 15.5 years) were prospectively enrolled in three academic hospitals. Cardiac MRI including Modified Look - Locker Inversion recovery T1 mapping sequence was performed using a 3-Tesla system with a different type of scanner for each hospital. Native T1 and ECV were measured in the short-axis T1
Rationale and Objectives Accurate differential diagnosis is essential because cardiac tumors and thrombi have different prognoses and therapeutic approaches. Native T1 map provides an objective T1 time quantifications of cardiac mass without the need for a contrast agent. We examined the diagnostic performance of radiomics features for differentiating cardiac tumors from thrombi using cardiac magnetic resonance imaging T1 mapping technique compared to that of late gadolinium enhancement (LGE) imaging. Materials and Methods This retrospective study included 22 cardiac tumors and 21 thrombi of 4
The image quality and diagnostic accuracy of T1-mapping-based synthetic late gadolinium enhancement imaging: comparison with conventional late gadolinium enhancement imaging in real-life clinical situation Backgrounds Synthetic late gadolinium enhancement (LGE) images are less sensitive to inversion time (TI) and robust to motion artifact, because it is generated retrospectively by post-contrast T1-mapping images. To explore the clinical applicability of synthetic LGE, we investigated the image quality and diagnostic accuracy of synthetic LGE images, in comparison to that of conventional LGE f
Objectives To evaluate the quality of radiomics studies using cardiac magnetic resonance imaging (CMR) according to the radiomics quality score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) guidelines, and the standards defined by the Image Biomarker Standardization Initiative (IBSI) and identify areas needing improvement. Materials and methods PubMed and Embase were searched to identify radiomics studies using CMR until March 10, 2021. Of the 259 identified articles, 32 relevant original research articles were included. Studies
Purpose To confirm that the image quality of coronary computed tomography (CT) angiography with a low tube voltage (80 to 100 kVp), iterative reconstruction, and low-concentration contrast agents (iodixanol 270 to 320 mgI/mL) was not inferior to that with conventional high tube voltage (120 kVp) and high-concentration contrast agent (iopamidol 370 mgI/mL). Materials and Methods This prospective, multicenter, noninferiority, randomized trial enrolled a total of 318 patients from 8 clinical sites. All patients were randomly assigned 1: 1: 1 for each contrast medium of 270, 320, and 370 mgI/mL. C
BACKGROUND Current methods for calculating the myocardial extracellular volume (ECV) fraction require blood sampling to determine the serum hematocrit. Synthetic hematocrit and thus synthetic ECV may be derived using unenhanced attenuation of blood. By use of virtual unenhanced (VUE) attenuation of blood, contrast-enhanced dual-energy CT (DECT) may allow synthetic ECV calculations without unenhanced acquisition. OBJECTIVE The purpose of this study was to compare synthetic ECV calculated using synthetic hematocrit derived from VUE images and conventional ECV calculated using serum hematocrit, b
Purpose This study aimed to assess the factors influencing aortic unfolding (AU) defined by aortic width on coronary artery calcium (CAC) scan and determine the normal limits for AU. Materials and Methods In this retrospective study, we measured AU in 924 asymptomatic subjects who underwent CAC scanning during routine health screening from June 2015 to June 2018. Multivariate regression analysis was used to evaluate the factors influencing AU. After the exclusion of subjects with risk factors associated with AU, 283 subjects were included in the analysis of normal values of AU. Mean AU, standa
A reliable, non-invasive diagnostic method is needed for early detection and serial monitoring of cardiotoxicity, a well-known side effect of chemotherapy. This study aimed to assess the feasibility of T1-mapping cardiac magnetic resonance imaging (CMR) for evaluating subclinical myocardial changes in a doxorubicin-induced cardiotoxicity rabbit model. Adult male New Zealand White rabbits were injected twice-weekly with doxorubicin and subjected to CMR on a clinical 3T MR system before and every 2–4 weeks post-drug administration. Native T1 and extracellular volume (ECV) values were measured at